pCOWeb +030220471 – rel. 1.0 – 02.05.2007 25
3. Open the window for setting the strings identifying the events for integer and analogue variables
(click point 3 in
Figure 4.n on page 23).
The settings in this window (
Figure 4.r) will only be used for e-mail and SNMP TRAP/INFORM
messages and will be common to the events generated by all the integer and analogue variables.
In the e-mail notifications, the suitable string will be automatically added to the “Subject” field,
separated by a dash; in the SNMP TRAP notifications, the OID will be included automatically, with the
corresponding string and contents, based on the event, as follows (see
6.2 on page 32):
1.3.6.1.4.1.9839.1.3.1.1.0 (OID for the Alarm fired event string)
1.3.6.1.4.1.9839.1.3.1.2.0 (OID for the Alarm reentered event string)
SETTINGS AVAILABLE:
¾ Alarm fired
: string that will be included in the notifications when the threshold is
exceeded.
¾ Alarm reentered
: string that will be included in the notifications when returning back
below the threshold, with hysteresis.
4.3.4 Setting the notifications set upon variations in the
variables
IMPORTANT
Some settings described below (“Event Handlers”, “Trap Configuration” and “E-Mail Configuration”) are also used for the scheduled events (see 4.3.5
on page 28).
NOTE: all the following settings are valid from when they are confirmed; the pCOWeb does not need to be rebooted.
PROCEDURE
1. Open the window for setting the events corresponding to the DIGITAL variables (click point 4 in
Figure 4.n on page 23).
A summary window is displayed for enabling the events relating to the variation of all the digital variables (
Figure 4.s below). Moving the mouse, for example,
over the section relating to digital variable 1 shows the tooltip “Digital Variable 1”; clicking opens the window, divided into three sections, for setting the
events linked to digital variable 1.
IMPORTANT: The Submit buttons only save the values for the corresponding section
.
Type: Digital Variable: 1
: the settings in window only refer to the digital variable with index 1.
Figure 4.r – Setting the strings sent for Activation -
Return
Figure 4.s - Events generated by digital variables